ARKEL ARCODE ELEVATOR CONTROL PANEL

ARKEL ARCODE ELEVATOR CONTROL PANEL

  • Connections with Cabin Units

Serial cabin communication on CanBus line
One to one connection between Control Panel and inspection box via plug-in flat cable
Single-out connection between COP and Revision box by single cable.

  • Connection with Floor Units

Serial communication via CanBus line or Parallel Communication by SP16 card
Shaft CanBus line which is extended all along of shaft and joined by plug-in cable from floor to floor.
Single-out connection on each floor connected to CanBus line of the shaft by plug-in cable for LOP.
Door Contact Connection
Door contact fittings extended all along of shaft and joined by plug-in cable from floor to floor.
For plug lock contacts of the floor doors, on each floor there
Pit bottom fittings

  • Plug-in connection with Pit Bottom Box via one single cable.

Car Positioning

  • By Encoder system
  • By Magnetic switches and Magnets

Automatic Door Control

  • All type of automatic door control
  • Independent door control according to stops by support of double door
  • Door control Input and Outputs (one piece in Revision Box and two piece in Control panel)

Indication types for COP

  • 5,7 inch color TFT display
  • 240 x 128 pixel graphic LCD display
  • 128 x 64 pixel graphic LCD display (horizontal/vertical)
  • 2x30mm dot matrix display
  • 3x30mm dot matrix display

Call/display Module options for LOP

  • 240 X 128 pixel graphic LCD display (on the door)
  • 128 x 64 pixel graphic LCD display (vertical)
  • 2x30mm dot matrıx display
  • 3x30mm dot matrix display
  • No display call board

Automatic bringing back to the floor

  • Easy way of comıng to a desired floor via 1 phase 220VAC UPS or with a connectiın to the battery groups.

Door bridging

  • Door early opening and open door level renovation is possible through door bridging circuit on DBR Board.

Motor-phase protection

  • With Output and Inputs on the Control Panel

Programmable Input and Outputs

  • Freely programmable Inputs and Outputs on Motherboard, cabin and floor cards.

Test function

  • Special test function to check COP and LOP connections

Distance control

  • With hand terminal connected to CANBUS line, it is possible to control ARCODE from any position.

Cabin – Shaft Power Supply

  • Protected from fault current, cabin and shaft supply brakers.

Shaft Lightning Control

  • Shaft Lightnening by impulse current switch (via buttons from the top of the cabin and the pit bottom)

Emergency Alarm

  • The siren of emergency alarm (via buttons from the top of the cabin and the pit bottom)

Safety circuit connections

  • Special connections for safety circuit in Control Panel, Revision Box and Pit Box

Conformity

  • EMC test report
  • As a whole elevator control system it is compatible with EN81-20 standardClick to buy this product online.
  • Number of stops: 64 stop
  • Drive type: Steeples speed
  • Gearless Machine (MRL or without machine room) / Geared Machine (MR or with Machine room)
  • Elevator spped: up tp ….. m/s
  • Control type: single button collection / double button collection
  • Group control: up to 8 elevators