VVVF MR ELEVATOR ARL 500 CONTROL PANEL

VVVF MR ELEVATOR ARL 500 CONTROL PANEL

-p; Connections with Cabin Units
Serial cabin communication through CanBus line
One to one connection between Control Panel and inspection box via plug-in flat cable
Single-out connection between COP and Revision box by single cable.
-p; Connection with Floor Units
Serial communication via CanBus line
Shaft CanBus line which is extended all along of shaft and joined by plug-in cable from floor to floor.
For LOP, single-out connection by plug-in cable on each floor connected to CanBus line of the shaft.
Door Contact Connection
Door contact connection extended all along of shaft and joined by plug-in cable from floor to floor.
For plug lock contacts of the floor doors, on each floor, there is a connection via plug-in cable with the door contacts.
Pit bottom Connection
-p; Connection with Pit Box via one plug-in single cable.
Car Positioning
-p; By Encoder system
-p; Or via Magnetic switches and Magnets
Automatic Door Control
-p; All type of automatic door control
-p; Independent door control according to stops by the support of the double door
-p; Door control Input and Outputs (one piece in Revision Box and two piece in Control panel)
Indication types for COP
-p; 240 x 128 pixel graphic LCD display
-p; 128 x 64 pixel graphic LCD display (horizontal/vertical)
-p; 2x30mm dot matrix display
-p; 3x30mm dot matrix display
Call/display Module options for LOP
-p; 240 X 128 pixel graphic LCD display (on the door)
-p; 128 x 64 pixel graphic LCD display (vertical)
-p; 2x30mm dot matrıx display
-p; 3x30mm dot matrix display
-p; No display call board
-p; Bringing back to the floor (for Electronic Elevators)
Via bringing back AKUS-SD card which is integrated to control panel.
-p; Urgently returnıng down the system (for Hydraulic elevators)
Via ARL-SARJ card and 2 piece of 12V battery
-p; Door Bridging
Early door openning and renewing open door level via door bridging circuit on a control board
-p; Motor – phase protection
Via Input-Outputs on the Control Board
-p; Programmable Input-Outputs
Freely programmable Inputs and Outputs on motherboard, cabin and floor cards.
-p; Test Functions
Special Test function to check the connections between COP and LOP.
-p; Distance Control
Via hand terminal connected to CANbus line, you can control ARL500 motherboard and Adrive speed control from any point.
-p; Cabin – Shaft Power Supply
Protected from fault current, cabin, and shaft supply brakers.
-p; Shaft Lightning Control
Shaft Lightnening by impulse current switch (via buttons from the top of the cabin and the pit bottom)
-p; Emergency Alarm
The siren of emergency alarm (via buttons from the top of the cabin and the pit bottom)
-p; Safety circuit connections
On Control Panel, Revision Box and Pit Box there are special connections for safety circuit
-p; Conformity
-p; EMC test report
-p; As a whole elevator control system, it is compatible with EN81-20 standard

Click to buy this product online.

  • Number of stops: 48 Stop
  • Drive type: Two Speed/ Hydraulic/ Infinitely Fast / Geared Machine / Gearless Machine
  • Elevator Speed: up to 2,5 m/s
  • Control Type: Single button collection / Double button collection
  • Group Control: up to 8 elevators
  • Serial Communication: with Cabin and LOP via CANbus
  • Automatic Door Control: according to each stop Automatic Double Door Control